800-654-7797 | Personal Emergency Reporting System

Durability and Versatility for Emergency Reporting Solutions

Create a customized and comprehensive Personal Emergency

Reporting System with the Linear  Medical Alert System -2400B.

Features and Functions

The  Medical Alert System -2400B table-top or wall-mount Console provides pushbutton

emergency assistance to anyone who desires additional security and peace

of mind. Designed for use with a suite of wireless personal transmitters and

accessories, the  Medical Alert System -2400B is the hub of one of the most successful and

durable emergency reporting systems available. With the optional VB-4B

voice board, the system combines a powerful speaker and sensitive microphone

in a proven solution for emergency two-way voice communications.

Simple Operation

Pushbutton Emergency Assistance – A button press on the Console or

wireless transmitter automatically places a call to the Emergency Monitoring

Center, staffed 24 hours a day by trained professionals. Operators then

notify pre-selected contacts to respond in specific situations.

Multiple Channels – Capable of reporting individual emergency alarms for

up to 16 subscribers.

Silent Alarm and Alarm Tones – Provides silent alarm capability (as panic

button for domestic violence applications) and separate tones for emergency,

fire and CO conditions.

Built-In Activity Timer Monitors household activity when turned on (system

default is off). Set for 8, 12 or 24-hour operation, the emergency alarm will

trigger automatically if the time set elapses before an activity transmitter is

triggered, or before the Consoles HOME button is pressed.

• Aid for the Visually Impaired Molded braille characters identify each Console

button function.

Flexible Notification The Consoles digital communicator conveys the

appropriate alarm report to the Emergency Monitoring Center via the standard

telephone or broadband network, along with audible and visual indicators.

Programmable Call Capability –Allows the Console to call three different

telephone numbers: primary, secondary and supervisory.

Personal Wireless Transmitters Effective signal coverage extends throughout

the house and outdoors.

Supervision and Auto-Test

Transmitter Status Reporting & Supervision - Optional status reporting mode

allows the transmitter to be paired with zone supervision at the Console for

automatic “sensor status trouble” reporting.

Transmitter Low Battery Monitoring Under normal operating conditions,

the transmitter detects low battery voltage and provides a status report to

its Console.

System Auto Test The console can be programmed to provide a system

periodic test reporton a 1, 7 or 30 day interval to the central monitoring station.

Effortless Installation

• Easy Installation and Programming Set up is made easy by Linears RA-2400

remote access software.

Tested for Reliability – UL listed as Home Healthcare Signaling Equipment per

Standard 1637.

Options For Expanded Utility

Installation and use of a variety of optional equipment broadens the

 Medical Alert System -2400B’s utility.

The VB-4B Voice Board

• Console Talks to User The digitized voice will sound emergency, fire, timer

done soon, and other system operation, set-up, and supervisory prompts

from a 38-word vocabulary.

Two-Way Voice Capability Subscribers talk directly to Emergency

Monitoring Center professionals via 2-way voice activated, 2-way

manual, or 1-way listen-only audio communications.

Speakerphone Capability The Console will monitor the telephone line for

an incoming call. Activating any emergency transmitter (or the Console’s

EMERGENCY button) while the telephone is ringing will cause the Console

to seize the line and begin full duplex voice communications. Activating

any emergency transmitter (or EMERGENCY button) during the call will

disconnect the line. The Console will auto-disconnect after 15, 30, or 60

minutes (programmable).

Smoke Detector

• The DXS-73 Supervised Photoelectric Smoke Detector will sound a loud

alarm when smoke is detected, Twenty seconds after the local alarm sounds,

the built-in transmitter sends a digitally coded wireless signal to the  Medical Alert System

console. The wireless signal will be repeated every 20 seconds as long as

smoke is still present.

Carbon Monoxide Detector

• The DXS-80 Carbon Monoxide Detector will initiate an automatic call to the

Emergency Monitoring Center. Warning tones will be sounded by the console

and the detectors will alert the subscriber, even during sleep.

Versatile personal transmitters

can be worn as a pendant,

wrist band or clipped to a

belt or pocket.

Compatible Supervised Stationary Transmitters

PRODUCT

MODEL

NUMBER

DESCRIPTION

DXS-31

SST00073

Supervised Universal Door/Window Transmitter

(for emergency and inactivity reporting)

Supervised Universal Door/Window transmitter with built-in

magnetic switch, accepts N/O or N/C external devices,

supervised for low battery and sends hourly status signals

DXS-32

SST00100

Supervised Miniature Door/Window Transmitter

Supervised miniature Door/Window transmitter with built-in

magnetic switch, supervised for low battery and sends

hourly status signals

DXS-54

SST00074

Supervised Passive Infrared Motion Detector

(for inactivity reporting)

Supervised passive infrared motion sensor with built-in

transmitter, supervised for low battery and sends hourly

status signals

DXS-73

SST00113

Supervised Photoelectric Smoke Detector

Supervised photoelectric smoke detector with built-in

transmitter, supervised for low battery and sends hourly

status signals

DXS-80

SST00116

Supervised Carbon Monoxide Detector Transmitter

Supervised carbon monoxide (CO) detector with built-in

transmitter, supervised for low battery and sends hourly

status signals

Available Models and Accessories

PRODUCT

MODEL

NUMBER

DESCRIPTION

 Medical Alert System -2400B

SSC00062B

Personal Emergency Reporting System

Supervised emergency reporting system receiver/control,

monitors up to 16 transmitters, can be manually started,

activity timer option, two-way voice option,point-ID reporting

allows multiple users

VB-4B

AAE00419B

2-way Audio Module with Voice Prompts

Two-way audio and voice prompt board for the  Medical Alert System -2400B

RJ-ADAPT

AAE00435

RJ-31X Telephone Adapter

RJ-31X adapter for  Medical Alert System -2400B Console

RSM-1

CAE00191

Remote Speaker/Microphone

External Remote Speaker / Microphone kit for Two-Way voice

for the  Medical Alert System -2400B or  Medical Alert System -3600B, comes in an attractive

plastic case that houses an 8-ohm speaker and microphone,

unit can be tabletop or wall mounted

Compatible Supervised Portable Transmitters (DXS Format)

PRODUCT

MODEL

NUMBER

DESCRIPTION

DXS-62A

SST00090A

Supervised 1-Button, 1-Channel Water-Resistant

Wristband/Pendant Transmitter

Miniature one button, one-channel, water-resistant, supervised

transmitter designed for use in emergency applications, includes

adjustable lanyard with breakaway release, wrist band and belt/

pocket clip, visual activation indicator.

DXS-64

SST00112

Supervised 1-Button, 1 Channel Pendant Transmitter

Pendant style water-resistant transmitter designed for use

in emergency applications, includes adjustable lanyard with

breakaway release, visual activation indicator

DXS-LRW

SST00123

Supervised 1-Button, Long-Range Wristwatch Transmitter

Wrist version of the LR transmitter series, designed for use in

emergency applications. Updated design, shock and water-

resistant*, supervised transmitter with improved transmission

range and two-color visual activation indicator. Capable of field

enrolling with compatible panels and consoles.

DXS-LRP

SST00122 (White) Supervised 1-Button, Long-Range Pendant Transmitter

SST00126 (Black) Pendant version of the LR transmitter series, with performance

features as listed in the DXS-LRW. Product is provided factory

pre-assembled on an adjustable lanyard with a breakaway release.

* LR Transmitters - water resistant up to 30 minutes at a depth

of three feet

DXS-65

SST00121

Supervised Emergency Alarm Transmitter

Supervised emergency transmitter with large HELP button,

LED transmission indicator, for wall mounting or tabletop use,

extra blank aqua button included

Specifications

R A D I O

Transmitter Capacity: 16 DX or DXS devices

Operating Frequency: 315 MHz

RF Format: Linear DX, DXS

Receiver Type: Dual diversity, superheterodyne

RF Programming Method: Linear quick-learn

C O M M U N I C A T I O N S

Communicator Formats: Contact ID and 4 x 2

Dialing Method: Pulse or tone dialing formats, field-enabled

Communicator Reports:

a. All transmitter alarms

b. All transmitter trouble

Supervisory

Low battery

c. All inactivity alarm reports

d. AC power failure

e. AC power restored

f. Console low battery

g. Console emergency alarm

C O N S O L E

Controls:

a. EMERGENCY: Large round button with multiple

actuation points, Braille characters

b. CLEAR: Momentary for system reset, call cancellation

c. HOME: Momentary to reset timer or press and hold for

5 seconds to disable the function

d. POWER SWITCH: Controls 120 VAC source, as well as

the backup battery

Indicators: Four LEDs

(POWER, TROUBLE, SENDING, HOME)

Connections:

a. In and out telephone jacks

b. External speaker, dialer output, and dialer power terminals

Outputs: One form C relay output activated upon initiation

of any alarm condition

ARMGUARD SECURITY | ME D I C A L | T e l e ma t r y |

h t t p : / / w w w . a r m g u a r d . c o m

Programming Method: Via RA-2400 remote access software

Inactivity Timer: Software programmable for 8, 12, or

24 hour cycles

Silent Alarm Feature: Software programmable per channel

Delayed Alarm Feature: Software programmable per

channel; delay time 15 or 30 minutes; note that an alarm

will not be transmitted if alarming transmitter sends a

restore signal to the console prior to delay timer timeout

Selectable Two-Way Voice Activation: Software program-

mable per channel

Speakerphone Option: Software programmable; call duration

time selectable for 15, 30, or 60 minutes

Pulse/Tone Dialing: Software or console programmable

Audible Output: Integral siren

Output Tones: Distinct alarm tones provided for emergency

and fire alarm conditions; provisions for timer reset tone also

incorporated into system

Dimensions: 8.75 in L x 7.50 inW x 3.00 in H

(222 x 190 x 76 mm)

Backup Battery: Recommended battery is 12V, 1.2 amp-hour;

Linear part number 100104

Backup Period: 32 hours minimum with VB-4B voice board

installed in the unit

Accessories:

a. Optional VB-4B two-way voice, voice prompt board

b. Optional RSM-1 Remote Speaker/Microphone

Listing: UL per Standard 1637, Home Healthcare Signaling

Equipment

Note: The optional RSM-1 is not UL-listed and is not intended

to be used in a UL-listed Medical Alert System system.

For more information, please visit www.linearcorp.com.

Specifications subject to change without notice.

UL1637 LISTED

Los Angeles, CA 90034 | 800.654.7797 |